Regency Indoor Fireplace L676S LP1 User Guide

Regency L676-1 Sunrise Gas Fireplace  
L676-1 Sunrise Gas Fireplace  
Framing Dimensions:  
Model  
L676S-NG1  
Natural Gas  
L676S-LP1  
Propane  
Framing Dimensions  
Description  
Framing Width  
Framing Height***  
Framing Depth  
L676S-1  
43” (1092mm)  
Fuel Type  
J
Minimum Supply Pressure  
Manifold Pressure - High  
Manifold Pressure - Low  
Orice Size  
5” W.C. (1.25 kPa)  
3.5” W.C. (0.87 kPa)  
1.6” W.C. (0.40 kPa)  
#37 DMS  
12” W.C. (2.98 kPa)  
10” W.C . (2.49 kPa)  
6.4” W.C (1.59kPa)  
#53 DMS  
K***  
L
45-7/8” (1165mm)*** + Hearth  
24-1/2” (622mm)  
M
N
Minimum Height to Combustibles  
Corner Wall Length  
56-1/4” (1429mm)  
57-3/16” (1453mm)  
80-13/16” (2052mm)  
49-1/4” (1251mm)  
15-9/16 (395mm)  
2” (51mm)  
O
P
Corner Facing Wall Width  
Vent Centerline Height  
Minimum Input  
Altitude 0-4500 ft. (0-1372m)  
19,500 BTU/h  
(5.71 kW)  
21,000 BTU/h  
(6.15kW)  
Q
R
Non-combustible Facing Height  
Gas Connection Opening Height  
Gas Connection Height  
Maximum Input  
Altitude 0-4500 ft. (0-1372m)  
29,000 BTU/h  
(8.49 kW)  
26,000 BTU/h  
(7.61kW)  
S
11-1/4” (286mm)  
5-3/4” (146mm)  
5” (127mm)  
T
Gas Connection Inset  
Vent Sizing  
5” Inner / 8” Outer  
5” Inner / 8” Outer  
U
Gas Connection Opening Width  
***Important: Framing height requires consideration of the hearth  
Approved Venting Systems  
depth. Dimension K = K + the thickness of installed hearth.  
Flex Vent Systems:  
FPI AstroCap™ Flex Vent  
Rigid Pipe Vent Systems:  
Simpson Direct Vent Pro®  
Selkirk Direct-Temp™  
Metal-Fab® Sure Seal  
Unit Dimensions:  
Unit Dimensions  
Description  
L676S-1  
A
B
C
D
E
F
G
H
I
Firebox Width w/ Standoff  
Rear Firebox Width  
Firebox Height  
42-1/2” (1080mm)  
33-1/8” (841mm)  
37-3/8” (949mm)  
45-5/8” (1159mm)  
24” (610mm)  
Height w/ Standoff  
Unit Depth  
Height to Vent  
40-3/8” (1026mm)  
29-1/16” (738mm)  
31-5/8” (803mm)  
3” (76mm)  
Fireplace Opening Height  
Fireplace Opening Width  
Height to Fireplace Opening  
Non-Combustible Requirements:  
Metal  
44-1/2"  
Stud  
(1130mm)  
Non-combustible  
Material  
31-5/8"  
(803mm)  
This manual is intended to be a Sales Reference Guide only.  
Do NOT use for actual framing and installation of any unit.  
Some specications may change without notice.  
You must use the actual manual for exact installation specications.  
WARNING  
Non-combustible Material  
Failure to maintain required clearances is a major cause of chimney related res.  
Finished Floor  
6-7/16"  
(163mm)  
3"  
Installation of this replace must comply with these clearances  
(76mm)  
Please note: Due to ongoing product development, product appearance and specications  
are subject to change without notice.  
 
Regency L676-1 Sunrise Gas Fireplace  
L676-1 Sunrise Gas Fireplace  
Vertical Terminations:  
Clearance Requirements:  
Installed  
Close to Floor  
Installed Close  
to Ceiling  
Clearance:  
Dimension  
16-1/2” (419mm)  
14-3/4” (375mm)  
52” (1321mm)  
13” (330mm)  
Measured From:  
A: Mantel Height  
B: Sidewall  
Minimum  
Side of replace opening  
Top of replace opening  
Maximum  
C: Ceiling  
D: Mantel Depth  
E: Alcove Width  
F: Alcove Depth  
84” (2134mm)  
36” (914mm)  
Sidewall to Sidewall (Minimum)  
Front to back wall (Maximum)  
Combustible Mantels  
Becauseoftheextremeheatthisreplaceemits,themantelclearances  
are critical. Combustible mantel clearances from top of the front facing  
are shown in the diagram below. Mantel may be installed anywhere in the  
shaded area or higher.  
Mantel  
From Top of  
Clearances Fireplace Opening  
A
B
C
D
31-1/16”  
26-1/2”  
17-1/2”  
16-1/2”  
Horizontal Terminations:  
Note:  
A non-combustible mantel may  
be installed at a lower height if  
the framing is made of metal  
studs covered with a non-com-  
bustible board.  
Ensure the paint that is used  
on the mantel and the facing is  
“heat resistant” or the paint may  
discolour.  
Mantel Leg  
Clearances  
Combustible mantel leg  
clearances as per diagram.  
Clearances are from the  
nished edge of the replace  
opening.  
 

Radio Shack Amplified Phone 43 3241 User Guide
RCA CRT Television F25339 User Guide
RCA CRT Television F36691 User Guide
Roland Computer Monitor DM 5 User Guide
Rose electronic Switch MAN V8 User Guide
Samsung Bluetooth Headset SCH A212 User Guide
Samsung Range DG68 00294A User Guide
Saturn Automobile 2007 Aura Hybrid User Guide
Sceptre Technologies Flat Panel Television E245BD FHDU User Guide
Sears Range 61011 User Guide